eq3configcmd und firmware file muss mit ausgeliefert und vor rfd-start geflasht werden - spätestens wenn Hmcon den 2.17er (cr)RFD nutzt (HmIP Support...)
hmcon auf RPI3/Jessie mit HM-CFG-LAN f/w 0.965,
rfd startet, funktioniert aber nicht (hmconfig hängt mit "lade Daten") und fällt immer nach ~ 1 Minute wieder aus.
Auch beim Start im Vordergrund gibt es reproduzierbar dieses Ausgabe:
root@raspberrypi:~# sudo -u hmcon /opt/hmcon/bin/rfd -c -f /opt/hmcon/etc/rfd.conf
2017/01/28 09:57:08.317 BidCoS-Service started
2017/01/28 09:57:08.318 XmlRpc Server is listening on TCP port 2001
2017/01/28 09:57:08.320 Default interface is now GEQ0208083
2017/01/28 09:57:08.320 Current AES key=0, previous AES key=0
2017/01/28 09:57:10.452 Connected to Lan Interface GEQ0208083 at 10.10.10.48
2017/01/28 09:57:10.452 Event: GEQ0208083.CONNECTED=true
2017/01/28 09:57:18.467 GEQ0208083 RX: HHM-LAN-IF,03C5,GEQ0208083,12FD7D,12FD7D,00013506,0000,00
2017/01/28 09:57:28.583 GEQ0208083 RX: HHM-LAN-IF,03C5,GEQ0208083,12FD7D,12FD7D,00015C8B,0000,00
2017/01/28 09:57:39.270 GEQ0208083 RX: HHM-LAN-IF,03C5,GEQ0208083,12FD7D,12FD7D,0001864C,0000,00
2017/01/28 09:57:49.805 GEQ0208083 RX: HHM-LAN-IF,03C5,GEQ0208083,12FD7D,12FD7D,0001AF74,0000,00
2017/01/28 09:58:00.589 GEQ0208083 RX: HHM-LAN-IF,03C5,GEQ0208083,12FD7D,12FD7D,0001D996,0000,00
2017/01/28 09:58:11.031 GEQ0208083 RX: HHM-LAN-IF,03C5,GEQ0208083,12FD7D,12FD7D,00020261,0000,00
2017/01/28 09:58:21.199 GEQ0208083 RX: HHM-LAN-IF,03C5,GEQ0208083,12FD7D,12FD7D,00022A1A,0000,00
terminate called after throwing an instance of 'std::bad_alloc'
what(): std::bad_alloc
root@raspberrypi:~#
Konfiguration:
root@raspberrypi:/opt/hmcon/etc# cat rfd.conf
Listen Port = 2001
Log Destination = File
Log Filename = /opt/hmcon/var/log/rfd.log
Log Identifier = rfd
Log Level = 1
Persist Keys = 1
Device Description Dir = /opt/hmcon/firmware/rftypes
Device Files Dir = /opt/hmcon/var/rfd/devices
Key File = /opt/hmcon/var/rfd/keys
Address File = /opt/hmcon/etc/rfd/ids
Firmware Dir = /opt/hmcon/firmware
User Firmware Dir = /opt/hmcon/var/firmware
XmlRpcHandlersFile = /opt/hmcon/var/RFD.handlers
Replacemap File = /opt/hmcon/firmware/rftypes/replaceMap/rfReplaceMap.xml
[Interface 0]
Type = Lan Interface
Serial Number = GEQ0208083
Encryption Key =
root@raspberrypi:/opt/hmcon/etc#
!!!!!!! NACHTRAG: rfd alloziert in der Tat ~670MB (!) Speicher und crashed dann, der core-Dump ist 670MB groß ... bad.alloc ist also richtig.
Aber - warum verbraucht der Prozess soviel Speicher?
Hi Leute.
Schönes lightweight Projekt. Genau das was ich gesucht habe.
Nur habe ich mal eine Frage bezüglich dem Diensten rfd und hs485d.
Kann ich diese auch per XML::RPC ansprechen und mir die Daten bspw. per init schicken lassen, wie es bei der CCU ging?
Gruß Maik
gruppe dialout
Hallo,
ich gabe einen MomeMatic Funk LAN Gateway und möchte ihn mit IOBroker verbinden.
Wie kann ich ihn installieren und wo finde ich ihn dann. Bin Neuling.
Bitte um Hilfe
Vielen Dank
config erzeugen, erzeugung hm-manager config anpassen und startscript anlegen.
script für firmwareupdate des funkmoduls (falls notwendig wenn HM-MOD-UART erhältlich ist).
Node.js Restore Script soll CCU2-Backups einspielen können und dabei die Regadom parsen und Geräte-/Kanalnamen setzen.
Da mit der Zeit die Uhrzeit in den Thermostaten wegdriftet, sollte bei der Installation ein cronjob erzeugt werden, der regelmäßig eine Synchronisation mit der Systemzeit herstellt. Befehl:
/opt/hmcon/bin/SetInterfaceClock 127.0.0.1:2001
für den rfd.
Falls Reboot erforderlich am Ende Hinweis und Frage ob Reboot durchgeführt werden soll
I just installed hm-con on a RPI2 with ioBroker. Thus port 8081 ist still used.
I'd do some testing, but how communicate?
Das oben genannte Gerät wird nicht erkannt bzw es wird immer noch einem geänderten AES Key gefragt (hm-konfigurator) obwohl keiner gesetzt ist. Ich benutze einen hm-cfg-usb2 der mit hmcon wunderbar funktioniert. Schliesse ich diesen direkt an meinen normalen rechner an wird der Aktor einwandfrei erkannt. Wenn Logs oder Andere weitere angaben benötigt werden bitte anschreiben.
ResetFile = /dev/ccu2-ic200
or
ResetFile = /sys/class/gpio/gpio18/value
for the http://www.elv.de/homematic-funkmodul-fuer-raspberry-pi-bausatz.html
Mein rfd Dienst startet nicht richtig.
Wenn ich ihn starte dann bricht er nach knapp 1s ab.
In der Log steht nichts drinnen, auch wenn ich den Log Level auf 0 setze.
Das ist meine Config:
Listen Port = 2001
Log Destination = File
Log Filename = /opt/hmcon/var/log/rfd.log
Log Identifier = rfd
Log Level = 1
Persist Keys = 1
# PID File = /opt/hmcon/var/rfd/rfd.pid
# UDS File = /opt/hmcon/var/rfd/socket_rfd
Device Description Dir = /opt/hmcon/firmware/rftypes
Device Files Dir = /opt/hmcon/var/rfd/devices
Key File = /opt/hmcon/var/rfd/keys
Address File = /opt/hmcon/etc/rfd/ids
Firmware Dir = /opt/hmcon/firmware
User Firmware Dir = /opt/hmcon/var/firmware
XmlRpcHandlersFile = /opt/hmcon/var/RFD.handlers
Replacemap File = /opt/hmcon/firmware/rftypes/replaceMap/rfReplaceMap.xml
[Interface 0]
Type = HMLGW2
Description = HM-LGW-O-TW-W-EU
Serial Number = MEQadasdasd
Encryption Key = asdasdasd
Und das ist meine Log
2016/04/11 20:25:26.076 <Info> BidCoS-Service started
2016/04/11 20:25:26.079 <Info> XmlRpc Server is listening on TCP port 2001
2016/04/11 20:25:28.091 <Info> Found HomeMatic Lan Gateway with IP Address 10.0.50.67
Das wars, mehr sieht man da nicht.
crRFD statt RFD, neue Config-Files, multimacd, tty-Treiber, jvm, hmipserver.jar, ...
kommt wohl, weil $WIRED nicht angelegt wurde, wenn man das wired-modul nicht installiert.
Raspbian Jessie, HM-MOD-RPI-PCB, rfd, hm-manager, kein hs485d - das ist denke ich das am häufigsten anzutreffende Setup, sollte mit einer Command-Line Option ohne weitere Rückfragen installiert werden können.
Man müsste checken, ob die console schon deaktiviert ist, und nur rebooten, wenn nicht.
-> evtl. die Antwort des sed-commands für die cmdline.txt abfragen? Gibt der einen Fehlercode zurück, wenn nichts zum ersetzen gefunden wurde?
weil der String "SetupGPIO" nicht angelegt wird, wenn bei "Keep existing rfd.conf" mit Y (Standard) geantwortet wird.
Bei "Install Startscript for rfd" mit Y wird das Startscript erneut geschrieben, aber eben ohne den "SetupGPIO"-Teil.
Lösungsvorschlag: beim Startscript schreiben die rdf.conf auf HM-MOD-RPI-PCB prüfen und dort erst den "SetupGPIO"-String befüllen.
It seems that OpenHAB uses TclRegaScript for its RPC calls (see https://github.com/openhab/openhab/blob/master/bundles/binding/org.openhab.binding.homematic/src/main/java/org/openhab/binding/homematic/internal/communicator/client/CcuClient.java)
I'm using the Raspberry Pi module attached to GPIO. The HomeMatic web interface works, and I can control my devices with that.
There is some communication, because in the log I can see the Device ID of the Raspberry Pi CCU interface
2016-04-05 22:07:24.058 [INFO ] [.b.h.i.c.HomematicCommunicator] - Homematic ServerId[name=CCU,version=?,address=MEQ1...]
2016-04-05 22:07:24.071 [INFO ] [o.o.b.h.i.c.client.CcuClient ] - Starting CcuClient
2016-04-05 22:07:24.204 [INFO ] [b.h.i.communicator.StateHolder] - Loading Homematic datapoints
2016-04-05 22:07:24.384 [ERROR] [.b.h.i.c.HomematicCommunicator] - Could not start Homematic communicator: Connection refused
org.openhab.binding.homematic.internal.communicator.client.HomematicClientException: Connection refused
at org.openhab.binding.homematic.internal.communicator.client.CcuClient.sendScript(CcuClient.java:322) ~[bundlefile:na]
at org.openhab.binding.homematic.internal.communicator.client.CcuClient.sendScriptByName(CcuClient.java:254) ~[bundlefile:na]
at org.openhab.binding.homematic.internal.communicator.client.CcuClient.iterateAllDatapoints(CcuClient.java:126) ~[bundlefile:na]
at org.openhab.binding.homematic.internal.communicator.StateHolder.loadDatapoints(StateHolder.java:84) ~[bundlefile:na]
at org.openhab.binding.homematic.internal.communicator.HomematicCommunicator.start(HomematicCommunicator.java:93) ~[bundlefile:na]
at org.openhab.binding.homematic.internal.bus.HomematicBinding.updated(HomematicBinding.java:95) [bundlefile:na]
Is there a way to make your installer work with OpenHAB and its HomeMatic binding?
Ich bekomme bei der Installation folgende Fehlermeldung:
install startscript /etc/init.d/hm-manager (Y/n)?
update-rc.d: using dependency based boot sequencing
insserv: script hm-manager: service skeleton already provided!
insserv: exiting now!
update-rc.d: error: insserv rejected the script header
wieder die drei Fehlermeldungen
nach reboot läuft nichts
root@Test-Raspi2:~# sudo ./hmcon-setup.sh
sudo: ./hmcon-setup.sh: command not found
root@Test-Raspi2:~# chmod a+x hmcon-setup.sh
chmod: Zugriff auf „hmcon-setup.sh“ nicht möglich: Datei oder Verzeichnis nicht gefunden
When I installed hmcon, adding the user hmcon to group "gpio" failed, because there is no such group on my Raspberry Pi (RPI2B, Raspbian jessie).
Therefore the init of rdf fails because it can't write to the gpio-value file (no permission).
Also: this file is owned by user root, group root, so adding hmcon to the group "gpio" wouldn't solve this.
Google only brought up the tool gpio-admin in regards to the gpio-group. Do I have to install it?
If so, it would be nice, to add it to the dependencies/install it with the install-script.
Or is there another explanation for this issue?
Thanks,
Jonas
z.B. wenn das git-repo nicht geladen werden kann oder zu wenig Speicherplatz ist.
Ich würde öfter mal ein || exit
hinter wichtige commands setzen. Oder eine elegantere Lösung?
Mit set -e
am Anfang des Skripts wird abgebrochen, wenn einer der commands fehlschlägt. Ist vielleicht ein bisschen krass (Problem z.B. beim user Anlegen wenn schon existiert?)
whiptail o.Ä. statt read?
wenn rfd beim booten gestartet wird meldet er
<Error> CCU2CommController::init(): Init failed. Cannot reset coprocessor. (Hint: Cannot write reset)
nach /etc/init.d/rfd restart
funktioniert es dann. Vermute mal der startet zu früh (=vor udev?)
Versionierung ab 1.0 nach http://semver.org
Wenn am Schluss HM-Manager gestartet wird steht der Port nicht in der Ausgabe "listening on ip:port"
(nur ne kosmetische Sache)
Lösung: entweder Port aus der conf lesen oder die Ausgabe weglassen.
Oder einfach so lassen ;-)
Oder die Ausgabe vom hm-manager-Start-script machen lassen?
von wo, welche version? /usr/local oder debian paket nutzen?
für arm? https://github.com/nathanjohnson320/node_arm
oder weglassen und dem user überlassen?
Habe es größenwahnsinnig mit anderer Distro (gentoo auf bananapi) getestet.
Da muss noch git installiert werden
da gibt es außerdem kein apt-get.
alle anderen issues ebenfalls
Hallo
Ich finde das Projekt hat einen super Ansatz!
Ich bin noch relativ neu auf dem Gebiet und versuche nun seit Tagen
das Hmcon auf dem Raspberry Pi 2 zumlaufen zu bringen.
Leider läuft der Homematic Manager nicht.
Während der Installation gibt es mir folgenden Fehler aus:
gyp WARN EACCES user "hmcon" does not have permission to access the dev dir "/root/.node-gyp/4.2.1"
gyp WARN EACCES attempting to reinstall using temporary dev dir "/opt/hmcon/node_modules/homematic-manager/node_modules/socket.io/node_modules/engine.io/node_modules/ws/node_modules/utf-8-validate/.node-gyp"
make: Entering directory '/opt/hmcon/node_modules/homematic-manager/node_modules/socket.io/node_modules/engine.io/node_modules/ws/node_modules/utf-8-validate/build'
CXX(target) Release/obj.target/validation/src/validation.o
SOLINK_MODULE(target) Release/obj.target/validation.node
COPY Release/validation.node
make: Leaving directory '/opt/hmcon/node_modules/homematic-manager/node_modules/socket.io/node_modules/engine.io/node_modules/ws/node_modules/utf-8-validate/build'
Die Fehlermeldung erscheint 4 mal während des HomematicManager install Prozess.
Eventuell mache ich auch einfach irgend etwsa total Falsch....
Danke für den Support!!
Beste Grüsse
Silvan
Hi
da das OCCU Repo recht groß ist und man unnötig viel runterladen muss, wäre es Sinnvoller zuerst die Architektur zu Prüfen und dann mit
svn export https://github.com/eq-3/occu/tree/master/arm-gnueabihf
die notwendigen Bereiche runterladen
hmcon sollte eine bestimmte OCCU Version nutzen (bzw ein bestimmten Commit aus dem OCCU Repo). Wenn OCCU update erfolgt muss dann neue hmcon-Version erstellt werden.
A declarative, efficient, and flexible JavaScript library for building user interfaces.
🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.
TypeScript is a superset of JavaScript that compiles to clean JavaScript output.
An Open Source Machine Learning Framework for Everyone
The Web framework for perfectionists with deadlines.
A PHP framework for web artisans
Bring data to life with SVG, Canvas and HTML. 📊📈🎉
JavaScript (JS) is a lightweight interpreted programming language with first-class functions.
Some thing interesting about web. New door for the world.
A server is a program made to process requests and deliver data to clients.
Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.
Some thing interesting about visualization, use data art
Some thing interesting about game, make everyone happy.
We are working to build community through open source technology. NB: members must have two-factor auth.
Open source projects and samples from Microsoft.
Google ❤️ Open Source for everyone.
Alibaba Open Source for everyone
Data-Driven Documents codes.
China tencent open source team.